• INA740 digital power monitor DIN version

The Symbol : 95061

DC current, voltage, power, energy monitor

45.00
45.00
opak Add to wishlist
Shipping within 24 hours from the moment of positive payment authorization
Shipping price The Lack Of
The Availability Of Mało
Leave your phone

The INA740 is a I2C bus, digital power monitor with an integrated current sensing element along with a 16- bit delta-sigma ADC specifically designed for current sensing applications. The device can measure fullscale currents up to ±24 A (connector limit, chip limit is 35A) with common-mode voltage support from up to +85 V. The INA740 reports current, bus voltage, die temperature, power, energy and charge accumulation. The integrated temperature sensor is ±2.5°C accurate over the junction temperature range. The low offset and gain drift design of the INA740 allows the device to be used in precise systems that do not undergo multi-temperature calibration during system integration. Sensorcommunicates digitally on the I2C bus and is supported by LK4 controller.
The sensor board is equipped with a 4-position switch, which allows changing the internal address on the I2C bus and cooperation of 4 sensors at once.

Technical data:
  • current measurement range:      +/- 24A (both directions),
  • voltage measurement range:      85V,
  • internal resistance (shunt):         800 µΩ,
  • offset current:                                ±62.5 mA(max),
  • power monitoring accuracy:        ±1.6% (max),
  • energy and charge accuracy:       ±2.1% at 25°C (max),
  • temperature sensor accuracy:     ±1.5°C at 25°C (max),
  • resolution:                                       16bit
  • supply voltage:                               3,3V,
  • current wire size:                            AWG12-24,
  • DIN mounting                                  yes, 35mm,
  • sizes:                                                (L)63mmx(W)16mmx(H)44mm,
  • I2C bus cable lenght:                      27cm.

Start-up:
Sensor should be connected according to the drawing, for voltage measurement (and of course power and energy) the LK4 ground and the load ground must be common! In the case of an isolated system, only current measurement can be realized.

Safety Information

Before installing and using the device, please read the following recommendations:

Current and voltage range:

Current: The maximum continuous current through the connectors is ±24A. Do not exceed this value to avoid overheating or damage to the device.

Voltage: The device supports common-mode voltages up to 85V. Exceeding this limit may damage the measuring system.

Power supply:

The device requires a stable supply voltage of 3.3V.
It is implemented from the LK4 controller, if reading measurements is made on another device, make sure that the power supply meets these requirements and is adequately protected against overvoltages.

Mounting:

The device is designed for mounting on a 35mm DIN rail in a dry and well-ventilated place.

Avoid mounting near heat sources and in places exposed to moisture or condensation.

Wiring:

For the current connection, use wires with an appropriate cross-section (AWG12–24), adapted to the expected current load.

The wires should be securely attached to the terminals to ensure a good electrical connection and minimize the risk of overheating.

Safety of use:

Before making any changes to the wiring or configuration of the device, disconnect the power supply.

Do not touch exposed wires or terminals during operation.

If you suspect damage to the device (e.g. visible signs of overheating, mechanical damage), immediately disconnect it from the power supply and consult the manufacturer or authorized service.

Integration with other systems:

In the case of integration with other devices or systems, make sure that all components are electrically and mechanically compatible.

Observe the safety rules applicable to the entire system in which the device is installed.

Note: The manufacturer is not liable for damage resulting from incorrect installation, use other than for its intended purpose or failure to follow the above recommendations.

If you require additional information or have any questions regarding the safe use of this device, please contact the Tinycontrol technical department.