• Three-phase energy meter Eastron SDM630MCT Modbus + 3x SCT-T24 250A/5A sensor

The Symbol : ZESTAW-017

The three -phase SDM630MCT meter is designed to read electricity measurements through Modbus RTU. Works with the LAN device Controller V3.7. The device allows you to read definitely more energy network parameters than the simpler SDM72D-M counter. A set of 3 CT (transducers) ESCT-T24 250A/5A current sensors included.

650.00
650.00
opak Add to wishlist
Shipping within 24 hours
Shipping price The Lack Of
The Availability Of Mało
Leave your phone
  • Included
Three-phase energy meter Eastron SDM630M Modbus without CT's
459 459
The Amount Of : 1 opak
ESCT-T24 250A/5A sensor
63 63
The Amount Of : 3 opak

The three -phase SDM630MCT meter is designed to read electricity measurements through Modbus RTU. Works with the LAN device Controller V3.7. The device allows you to read definitely more energy network parameters than the simpler SDM72D-M counter.
A set of 3 CT (transducers) SCT-T24 250A/5A current sensors included.

WARNING - after selecting and approving the CT sensor meter in the menu - THIS CANNOT BE CHANGED!!! (MID certification condition)

The most important indications can be read from the meter:

  • Two -way active energy measurement: consumed (import), introduced into the network (export), summary
  • two -way measurement of reactive energy: downloaded (import), introduced into the network (export), summary
  • Measurements of voltage, currents, temporary temporary power, passive instantaneous power separately for each phase
  • Measurement of total active power (positive values - energy consumption, negative - energy introduction to the network
  • outputs: 2 impulse outputs, 1 RS-485 output, MODBUS-RTU protocol
  • Certified according to Directive EU 2014/32/EU
  • MID certificate number 0120 / SGS0151

Main applications (using LAN V3.5 controller)

  • Energy monitoring taken from the network (import) and introduced into the network (export) taking into account phases on the connection
  • Monitoring of the remaining network parameters on the connection
  • control of additional loads depending on the energy balance on the meter

Technical Specifications:

  • Auxliary Supply (Power supply for measurements connectors 5 and 6): Two-way fixed connector with 2-5 mm2 stranded wire capacity 85 to 275V AC 50/60Hz ±10% or 120V to 380V DC ±20%. Consumption < 10W.
  • Rated voltage: 3x230 V AC
  • Work voltage: 80% ÷ 120% UN (V)
  • AC voltage resistance: 4 kv -1m
  • Impact voltage resistance: 6kV -1.2μs
  • Electricity: 10 A
  • Maximum rated current: 100 A
  • Power consumption: <2w/10 VA per phase
  • Impulsive output: 400 IMP/KWH
  • Display: LCD
  • Working temperature: -25 ° C ÷ +55 ° C
  • Storage temperature: -40 ° C ÷ +70 ° C
  • Starting time: 10 seconds
  • Maximum registration indications: 6+1 - 999999.9
  • Protection degree: IP51
  • CT sensor: 3x ESCT-T24 250A/5A