• Three-phase energy meter Eastron SDM630MCT Modbus + 3 ESCT-T24 150A/5A sensor

The Symbol : ZESTAW-015

A set consisting of a three-phase SDM630MCT Modbus meter and three ESCT-T24 150A/5A current sensors (transducers).

698.70 -10% 628.83
698.70 -10% 628.83
Lowest price in the last 30 days:
445.61 548.1
opak Add to wishlist
Shipping within 24 hours from the moment of positive payment authorization
Shipping price Depends on the delivery location
Availability Few
Leave your phone
  • Included
ESCT-T24 150A/5A sensor
79.9 79.9
The Amount Of : 3 opak
Three-phase energy meter Eastron SDM630MCT Modbus
459 459
The Amount Of : 1 opak

A set consisting of a three-phase SDM630MCT Modbus meter and three ESCT-T24 150A/5A current sensors (transducers).


The three-phase meter SDM630MCT Modbus allows you to read electrical network parameters via the Modbus RTU bus.
Our Lan Controller series devices – LK3.5+, LK4, and LK4mini – support this meter, enabling integration with a remote monitoring system.

Compared to the simpler SDM72D-M model, the SDM630MCT Modbus meter offers access to a wider range of measurements, including voltage, current, and power for each phase separately, as well as total energy.

NOTE: Once the current transformer (CT) type is selected and confirmed in the meter menu, it cannot be changed!
This limitation is due to MID certification requirements.

Basic features

  • Bidirectional measurement of active energy: consumed (import), fed into the grid (export), total.
  • Bidirectional measurement of reactive energy: consumed (import), fed into the grid (export), total.
  • Measurements of voltage, current, active power, and reactive power separately for each phase.
  • Measurement of total active power (positive values ​​- energy consumption, negative values ​​- energy fed into the grid).
  • Outputs: 2 pulse outputs, 1 RS-485 output with Modbus RTU protocol.
  • Certified according to EU Directive 2014/32/EU.
  • MID certificate number 0120 / SGS0142.

Main applications (using the LAN Controller)

  • Monitoring of energy drawn from the grid (import) and fed into the grid (export), taking into account the phases at the connection point.
  • Monitoring of other grid parameters at the connection point.
  • Controlling the operation of additional loads depending on the energy balance on the meter.

Technical specifications

  • Power supply for measurements (connectors 5 and 6): connector with stranded wire 2÷5 mm², voltage from 85 to 275 V AC 50/60 Hz ±10% or 120 V to 380 V DC ±20%.
  • Nominal voltage (Un): 3 x 230 V AC
  • Operational voltage: 80% ÷ 120% of Un (V)
  • Voltage withstand: 4 KV for 1 minute
  • Impulse voltage withstand: 6 KV - 1.2 μS
  • Power consumption: < 2 W / 10 VA per phase
  • Display: LCD
  • Operating temperature: –25 °C ÷ +55 °C
  • Storage temperature: –40 °C ÷ +70 °C
  • Maximum reading: 9999999.9 kWh / kVarh
  • Protection rating: IP51
  • CT sensor: 3 x ESCT-T24 150A/5A
The Signature Of The